• Welcome to NextStar Technologies


    NextStar is your specialists in concrete crack repair for foundation and slab floor restoration. Polyurethane foam, Epoxy, Polyurea, Special Urethanes and Carbon Fiber for concrete. National # 1-866-445-3984

    NextStar technologies concrete cracks foundation resoration injection and repair Concrete floor repair products
  • Online Store

    Quality Supply

    Concrete crack repair products are used by contractors and professionals for foundation crack and slab repair.  Also offering a select line of D-I-Y products to the general public. Enter Here

    concrete crack repair products polyurethane and epoxy injection kits and supplies
  • Foundation Crack Repair Kits

    Concrete Crack

    Premium Polyurethane foam or Epoxy injection for basement concrete foundation cracks, to stop leaking foundations or repair of structural foundation walls using Epoxy.

    concrete foundation crack repair with urethane foam or epoxy
  • Repair of broken concrete slab floors

    Slab Floors

    Preferred solutions that can effectively repair common problems with broken or cracked concrete floor slabs. Solutions for structural repair of concrete slabs including carbon fiber solutions for reinforcement.

    concrete floor slab clack restoration and structural reinforcement
  • Concrete Reinforcement

    Carbon Fiber

    Carbon Fiber solutions for cracked or bowed concrete structurally reinforced with carbon fiber, stronger that steel but at a reduced cost. Carbon fiber provides a modern proven solution to an old problem and easy to apply.

    Concrete foundation reinforcemnet with carbon fiber stronger than steel
Concrete crack and foundation reair supplies for concrete crack injection and foundation repair Basement and foundation crack repair for leaking foundations Concrete floor cracks and slab restoration carbon fiber for concrete
 Sign in to Account Order Status View Shopping Cart
Moisture Vapor Emission 50 kits
NextStar-technologies-concrete-foundation-crack-injection-repairItem DetailsPolurethane-crack-injection-kits
Moisture Vapor Emission 50 kits
Item Name:

Moisture Vapor Emission 50 kits

Item #:
$425.00 USD
Average Rating:
NextStar-technologies-concrete-foundation-crack-injection-repairItem OptionsPolurethane-crack-injection-kits
AWS-100 Digital Scale
100x 0.01g Digital Scale (Add $24.95 USD)
NextStar-technologies-concrete-foundation-crack-injection-repairItem PricePolurethane-crack-injection-kits
Your Price:  In Stock
$425.00 USD Quantity:  UpdateAdd to Shopping cart

Product Image Gallery:

Calcium Chloride Concrete Moisture & Alkalinity Test Kit  50 Kits
Authorized Distributer of VaporGuage products Calcium Chloride Concrete Moisture & Alkalinity test kits
Test your moisture vapor transmission rate before coating concrete slabs with :
Epoxies, Paints, Polyaspartics, Glues, Standard floor coverings to make sure you do not have a future floor coating failure. Check with the manufaturer as to what the acceptable limit is for vapor transission rate for the desired product.

This anhydrous calcium chloride vapor test kit was developed over 40 years ago to quantify the volume of water vapor radiationg from a concrete slab surface over time. This test is directly specified by the vast majority of the Floor Covering Industry as the primary measure of moisture acceptability for floor covering installation.

Use this test to model the amount of moisture that emits from 1,000 square feet of slab surface in 24 hours. The result is expressed in pounds which is the equivalent weight of water, emitted as vapor, over 1,000 square feet in 24 hours. Use this result to compare to the manufacturere's specifications for floor covering or coating tolerances. Always reference a copy of the manufacturer's specifications when reporting results using this test. Most manufacturers select the industry standard of 3lbs vapor pressure per 1000sq ft as a maximum for coating or covering concrete before treatments are required to reduce the vapor level.

This test requires the use of a gram-weight scale with a graduation of 1/10th (0.1) gram. The calcium chloride container is weighed before and after exposure to the concrete slab. It is highly recommended that the test be weighed prior to, and directly after exposure using the same scale to ensure uniformity and accuracy of test results

3 Pack of test kits
Testing of moisture levels in concrete for coatings or flooring is an easy and low cost test method that anyone can do with a gram scale download instructions and see.
Easy to test and see results
(.1) gram scale needed

Test Instructions

Concrete Moisture & Alkalinity Testing Instructions:
Survey Job Site Conditions
Verify that the building’s environmental controls are operational. The building temperature and humidity should be representative of what it would be during normal use. The temperature should be between 65° F to 85° F  or 18° C to 25° C and the relative humidity between 40% and 60% for minimum of 48 hours prior to conducting tests.
Schedule Accordingly
On the first day preparation will take place. On the following day the tests should be set and then later retrieved in 60 to 72 hours. The tests need to remain undisturbed for a minimum of 60 hours and a maximum of 72 hours.
Test Location & Frequency
Place tests throughout the area with some in the middle of the building, at the perimeter, over cracks and joints and especially in area of potential moisture. The tests should be performed at a rate of three tests for the first 1,000 square feet and one additional test for each 1,000 square feet.
Test Site Preparation
Remove foreign substances such as adhesives, curing compounds, sealers and floor covering materials. Before removing foreign substances and/or preparing the test site verify that the existing materials do not contain asbestos and/or lead. Prepare a 20” x 20” test site by mechanical means (diamond cup wheel on grinder if possible) and leave exposed a minimum of 24 hours prior to setting the tests.
Weigh Calcium Chloride Container
Remove calcium chloride from the packing and weigh with a gram scale capable of measuring 0.1 gram. Do not remove tape prior to weighing. To assure more accurate results always weigh tests on site and just prior to setting. Record the weight and time on the dish label. Remove tape from calcium chloride container and adhere to the outside of dome to check for leaks.
Placing Dome Cover
Remove dish lid and place underneath the bottom piece. Be careful not to spill any calcium chloride. Place open calcium chloride container on the center of the test site, remove gasket cover and adhere dome to the concrete surface. Press firmly on flange until gasket reaches the outer part of the flange. Press on the center of the dome to check for leaks.
Retrieving Calcium Chloride Container
Cut dome top with a box knife in a u-shape large enough to remove the calcium chloride container without spilling and calcium chloride. Replace dish lid cover, re-adhere tape and re-weigh. Record the weight and time on the dish label.
Perform Alkalinity Tests  (a pH of 7 is neutral )
Perform one alkalinity test for every calcium chloride test. Place a quarter-sized amount of the pre-packaged test solution on concrete surface. Let solution stand for sixty seconds and then place pH paper into water and let stand for five seconds. Remove pH paper and immediately compare to color chart. Chart included in kit. Record pH test results on the corresponding calcium chloride dish. High pH refers to High alkaline soil salts penetrating trough the slab. Check with manufactures specifications if you are treating or coating the concrete that it is compatible with high pH above 9.


Test your concrete slab before coatings or painting with a Moisture Emission Kit, Anhydrous Calcium Chloride vapor test kit.
Prevent concrete coating failures in advance and treat concrete before coating.
Your Online Foundation and Concrete crack repair store
ASP.NET Shopping Cart Software